Abstract:
Alumina, zirconia, and thoria were selected for use in composite ceramic heat shields for the leading surfaces of lifting orbital re-entry vehicles. Coated columbium and molybdenum were selected for substructure materials. Commercially available low and high density alumina, zirconia, and thoria ceramics were evaluated for thermal shock resistance; and many high density, but no low density ceramics were found to be satisfactory. A sintered low density (95 lb/ft^3) thermal shock resistace zirconia was developed, but it was difficult to reproducibly manufacture. A sintered low density (125 lb/ft^3) thoria was developed that had low thermal shock resistance but could be reproducibly manufactured. Chemically bonded low and high density thermal shock resistant varieties of alumina, zirconia, and thoria were developed. Thermophysical properties were determined to temperatures as high as 4500 F for the ceramics utilized in this project. Analytical techniques were derived for predicting the thermal stress behavior of ceramics. Twenty-two subscale heat shield modules and three full size components were designed, fabricated and environmentally tested. The full size components were a 3.0 inch radius, 3400F leading edge; a 1.5 inch radius, 4000F leading edge; anda 6.0 radius, 5000F nose cap. The ceramic phase densities for these components were 57 lb/ft^, 97 lb/ft^3, and 166 lb/ft^3 respectively. Satisfactory techniques were developed for processing, fabricating, and assembling ceramic heat shields. Typical launch vibration and acoustical environmental conditions were not found to be critical, but re-entry thermal environment was found to be very critical. A MAPP-0X thermal test facility was developed for full scale testing. The 1.5 inch radius leading edge survived thermal testing although testing was prematurely terminated due to a test fixture failure. During thermal testing, the 3.0 inch readius leading edge cracked but remained intact and did not spall; and the 6.0 inch radius nose cap underwent severe surface erosion. These two failures were attributed to a combination of design and material shortcomings and the severity of the MAPP-0X thermal test environment.

Provenance: Lockheed Martin Missiles & Fire Control

Other options for obtaining this report:

Via the Defense Technical Information Center (DTIC):
A record for this report, and possibly a pdf download of the report, exists at DTIC

Via National Technical Report Library:
This report may be available for download from NTRL. Use the Title from this record to locate the item in DTIC Online

Indications of Public Availability
No digital image of an index entry indicating public availability is currently available
There has been no verification of an indication of public availability from an inside cover statement



Export