Abstract:
This project was initiated to develop four prototype pressure transducers in the range of 0.0 to 0.1 psia for Wright-Patterson AFB. The design selected makes use of a convoluted diaphragm force collector to drive a cantilever beam. A semiconductor strain gage bridge bonded to the beam converts the force to an electrical signal which is amplified to provide a 0 to 5V dc output. The results presented demonstrate achievement of essentially all requirements, save high-temperature transient performance. It is apparent from the results of this project that an accurate 0.0 to 0.1 psia transducer of low weight and reasonably high natural frequency can be produced. Achievement of higher operating temperature and natural frequency is possible.

Provenance: Lockheed Martin Missiles & Fire Control

Other options for obtaining this report:

Via the Defense Technical Information Center (DTIC):
A record for this report, and possibly a pdf download of the report, exists at DTIC

Via National Technical Report Library:
This report may be available for download from NTRL. Use the Title from this record to locate the item in DTIC Online

Indications of Public Availability
No digital image of an index entry indicating public availability is currently available
There has been no verification of an indication of public availability from an inside cover statement



Export